GREASE TRAP

Galley water Treatment

The ECOtrap manual series treats the grey water from galley sink, using the following process:

  • First filtration of coarse particles by basket strainer;
  • chemical treatment by chemical dosage for the reduction of FOG (Fat, Oil, Grease) content.

COMPONENTS

The Grease Trap, ECOtrap manual, is comprised of the following parts, as standard supply: main tank, peristaltic pump (for chemical solution dosing), fat grease solution (supplied on 5 liters tank). Installation: under sink is recommended; with clea- rance maintenance to be left on the top of the tank.

OPERATION PRINCIPLE

The unit uses selected lipase producing bacte- ria, nutrients and enzymes in a buffer solution (Fat Grease Solution), to converts Fatty Acids in non-harmful CO2 and H2O, thus reducing FOG (Fat, Oil, Grease) to consent a safe discharge. The solu- tion is automatically dosed by the pump according to its settings.

Model (A) (B) (C) (D) (E) (F) Maximum Flow Rate
ECOTRAP 0 525 425 323 60 340 500 0.75
ECOTRAP 1 945 600 323 60 340 500 0.75
ECOTRAP 2 1005 660 414 60 340 620 1.25
ECOTRAP 3 1048 700 428 60 340 667 2.0
ECOTRAP 4 1208 840 455 89 356 718 2.75
ECOTRAP 5 1268 900 456 89 400 718 3.5
Dimensions (mm)